Car, MERCEDES, E 211, 211.606 E 220 CDI, 2005-2006, Automatic air conditioning (AAC)

Climate control - Automatic air conditioning (AAC) - 0

Identification

Production date: 06 10 11

Hardware number: 01.06

Software number: 10.06

Diagnostic version: 4.7

MB number for hardware: 16 95 45 19 08

Supplier: Kostal

Identifier: 04 07

DTC

9350: AC bus - communication error with C-AAC multifunction sensor

9465: Blower regulator - overload shutdown

9460: AC bus - communication error with right air mix flap motor

Controls

Clear DTC

Data stream

Evaporator temperature sensor: -99 °C

OCP: N70b1 (in-car temperature sensor): 22 °C

In-car temperature sensor: -99 °C

Ambient temperature sensor: 31 °C

Refrigerant pressure: 18 bar

Engine speed: 751

A/C compressor request: 0 %

A/C compressor torque: 0 N·m

A/C compressor - current consumption: 0 mA

Engine coolant temperature sensor: 255 °C

Left front sun sensor - light intensity: 0 %

Right front sun sensor - light intensity: 0 %

Left rear sun sensor - light intensity: 0 %

Right rear sun sensor - light intensity: 0 %

C-AAC sun sensor (4 in total) - total light intensity: 0 %

Terminal 58d: 0 %

Vehicle speed sensor: 0 km/h

Air mix flap motor - target left position: 20534

Left air mix flap motor - position: -9997

Left air mix flap adjustment motor - stored travel: 1913

Current left air mix flap adjustment motor travel: 1915

Lost communication between AAC pushbutton control module and left air mix flap motor: Yes

Left air mix flap motor - electrical fault: No

Left air mix flap motor - mechanical fault: Yes

Left air mix flap motor - excess temperature: No

Left air mix flap motor - position motors alignment: Ok

Right air mix flap actuator motor - target position: -9923

Right air mix flap actuator motor - position: -9817

Right air mix flap adjustment motor - stored travel: 1956

Right air mix flap adjustment motor - current travel: 1907

Lost communication between AAC pushbutton control module and right air mix flap motor: Yes

Right air mix flap motor - electrical fault: No

Right air mix flap motor - mechanical fault: Yes

Right air mix flap motor - excess temperature: No

Right air mix flap motor - position motors alignment: Ok

Defroster flap motor - target left position: -7624

Left defroster flap actuator - motor position: 12965

Left defroster flap adjustment motor - stored travel: 31541

Current left defroster flap adjustment motor travel: 45351

Lost communication between AAC pushbutton control module and left defroster flap motor: No

Left defroster flap actuator - electrical fault: Yes

Left defroster flap motor - mechanical fault: No

Left defroster flap actuator - excess temperature: Yes

Left defroster flap actuator - position motors alignment: Ok

Right defroster flap motor - target position: 24919

Right defroster flap motor - position: 12572

Right defroster flap adjustment motor - stored travel: 49252

Right defroster flap adjustment motor - current travel: 37175

Lost communication between AAC pushbutton control module and right defroster flap motor: Yes

Right defroster flap actuator - electrical fault: No

Right defroster flap motor - mechanical fault: Yes

Right defroster flap actuator - excess temperature: No

Right defroster flap actuator - position motors alignment: Ok

Right footwell flap motor - target position: 24883

Right footwell flap motor - position: 36229

Right footwell flap adjustment motor - stored travel: 49705

Right footwell flap adjustment motor - current travel: 41512

Lost communication between AAC pushbutton control module and right footwell flap motor: Yes

Right footwell flap motor - electrical fault: No

Right footwell flap motor - mechanical fault: Yes

Right footwell flap motor - excess temperature: No

Right footwell flap motor - position motor alignment: Ok

Footwell flap actuator motor - target left position: 23138

Left footwell flap motor - position: -3817

Left footwell flap adjustment motor - stored travel: -7929

Current left footwell flap adjustment motor travel: 2142

Lost communication between AAC pushbutton control module and left footwell flap motor: Yes

Left footwell flap actuator - electrical fault: No

Left footwell flap motor - mechanical fault: Yes

Left footwell flap actuator - excess temperature: No

Left footwell flap actuator - position motor alignment: Ok

Right center ventilation air flap motor - target position: 296

Right center ventilation air flap motor - position: -3454

Right center ventilation air flap adjustment motor - stored travel: 49704

Right center ventilation air flap adjustment motor - current travel: 42340

Lost communication between AAC pushbutton control module and right center ventilation air flap motor: Yes

Right center ventilation air flap motor - electrical fault: No

Right center ventilation air flap motor - mechanical fault: Yes

Right center ventilation air flap motor - excess temperature: No

Right center ventilation air flap motor - position motor alignment: Ok

Ventilation air flap motor - target left center position: 29256

Left center ventilation air flap actuator motor position: 20534

Left center ventilation air flap adjustment motor - stored travel: 29208

Current left center ventilation air flap adjustment motor travel: 2726

Lost communication between AAC pushbutton control module and left center ventilation air flap motor: Yes

Left center ventilation air flap motor electrical fault: No

Left center ventilation air flap motor mechanical fault: Yes

Left center ventilation air flap motor excess temperature: No

Left center ventilation air flap motor position motor alignment: Ok

Fresh/recirculation air flap motor - target value: -9997

Fresh/recirculation air flap motor: 15172

Fresh and recirculated air flaps adjustment motor - stored travel: 2114

Current fresh and recirculated air flaps - adjustment motor travel: 2119

Lost communication between AAC pushbutton control module and fresh and recirculated air flaps motor: Yes

Fresh and recirculation air flaps motor - electrical fault: No

Fresh and recirculation air flaps motor - mechanical fault: Yes

Fresh and recirculation air flaps motor - excess temperature: No

Fresh and recirculation air flaps motor - position motor alignment: Ok

Left rear air mix flap motor - target position: 45075

Left rear air mix flap motor - position: 49447

Left rear air mix flap adjustment motor - stored travel: 46691

Current left rear air mix flap adjustment motor travel: 49879

Lost communication between AAC pushbutton control module and left rear air mix flap motor: Yes

Left rear air mix flap motor - electrical fault: No

Left rear air mix flap motor - mechanical fault: Yes

Left rear air mix flap motor - excess temperature: No

Left rear air mix flap motor - position motor alignment: Ok

Right rear air mix flap motor - target position: 45075

Right rear air mix flap motor - position: 52070

Right rear air mix flap adjustment motor - stored travel: 41730

Right rear air mix flap adjustment motor - current travel: 8501

Lost communication between AAC pushbutton control module and right rear air mix flap motor: Yes

Right rear air mix flap motor - electrical fault: No

Right rear air mix flap motor - mechanical fault: Yes

Right rear air mix flap motor - excess temperature: No

Right rear air mix flap motor - position motor alignment: Ok

Blower regulator for requirement of blower capacity - target value: 18 %

Blower motor - current consumption: 1.6 A

Blower regulator - temperature: 1.0 °C

Blower regulator - supply voltage: 12.0 V

Multifunction sensor - CO value: 530

Multifunction sensor - NOx value: 354

Multifunction sensor - dewpoint temperature: 13 °C

Multifunction sensor - relative air humidity: 41

Multifunction sensor - current ambient temperature: 58 °C

Power supply: 12 V

Left heating capacity: 100 %

Right heating capacity: 100 %

DF signal (analog): 0 %

Cutoff because of overvoltage at terminal 30: No

Cutoff because of undervoltage at terminal 30: No

Shutdown due to excessive temperature: No

Generator output: Ok

PTC heater booster: Ok

PTC heater booster: 0 A

Heating element 1: short circuit: Not present

Heating element 2: short circuit: Not present

Heating element 3: short circuit: Not present

Heating element 4: short circuit: Not present

Heating element 5: short circuit: Not present

Heating element 6: short circuit: Not present

Heating element 7: short circuit: Not present

Heating element 8: short circuit: Not present

Heating element 1: open circuit: Not present

Heating element 2: open circuit: Not present

Heating element 3: open circuit: Not present

Heating element 4: open circuit: Not present

Heating element 5: open circuit: Not present

Heating element 6: open circuit: Not present

Heating element 7: open circuit: Not present

Heating element 8: open circuit: Not present

Actuators test

Controls

Heater booster

Left defroster flap motor

Right defroster flap motor

Left footwell flap motor

Right footwell flap motor

Left center ventilation air flap actuator motor, Left air mix flap motor

Right center ventilation air flap actuator motor, Right air mix flap motor

Left rear air mix flap motor

Right rear air mix flap motor

Left and right defroster flaps motor

Left and right footwell flaps motor

Center ventilation flap motor

Left and right air mix flaps motor

Fresh and recirculation air flaps motor

Activated charcoal filter flap adjustment motor

Blower motor

Engine/AC electric suction fan

Illumination

Display test images on the LCD display

Check of LEDs

A/C compressor relay

Blower of interior temperature sensor

Heat exchanger shutoff motor

Closing air recirculation flap (for cleaning)